ActiveCore Framework - Firmware Releases

Firmware releases for the following models: AVQ200, AVQ1020(2ndGen), AVQ1022(1stGen), AVQ1022(2ndGen)

FW15259 (November 5, 2021)

List of Changes

ChangeTypeApplicable ModelsApplicable Standards*
ATSC 1.0/3.0 spectrum shape fix (the lower shoulder misshapen at certain RF channels)FIXAVQ1022(1stG)ATSC 1.0/3.0
ATSC 3.0 STLTP analysis enhancement: 2D FEC scheme statisticsNEWAVQ1022(2ndG)ATSC 3.0

Links to Firmware Images

ModelLink
AVQ1022 (1stGen)Link
AVQ1022 (2ndGen)Link

Upgrade Instructions: Firmware and License Upgrade

IMPORTANT!
Please check your SLA license expiry date on the Control Panel -> Status page, section Versions and Serials Numbers, for the validity of the Firmware support. A firmware image will fail to install if the SLA is not active. Contact Avateq Support for more details.

FW15195 (October 14, 2021)

List of Changes

ChangeTypeApplicable ModelsApplicable Standards*
Shoulder Attenuation calculation fixedFIXALLATSC 3.0
NTP Communication fixedFIXAVQ1022(2ndG)NSS
SNMP unable to connect fixedFIXALLNSS
Email engine upgraded to connect to SMTP servers without authenticationNEWALLNSS
Email send statusNEWALLNSS
System time on Report to include Timezone shift and sync statusNEWALLNSS

* NSS - Not Standard Specific

Links to Firmware Images

ModelLink
AVQ200Link
AVQ1020 (2ndGen)Link
AVQ1022 (1stGen)Link
AVQ1022 (2ndGen)Link

Upgrade Instructions: Firmware and License Upgrade

IMPORTANT!
Please check your SLA license expiry date on the Control Panel -> Status page, section Versions and Serials Numbers, for the validity of the Firmware support. A firmware image will fail to install if the SLA is not active. Contact Avateq Support for more details.

FW13561 (July 7, 2020)

List of Changes

ChangeTypeApplicable ModelsApplicable Standards*
RF Board CalibrationFIXAVQ1022 (1stG)NSS

* NSS - Not Standard Specific

Links to Firmware Images

ModelLink
AVQ1022 (1stGen)Link

Upgrade Instructions: Firmware and License Upgrade

IMPORTANT!
Please check your SLA license expiry date on the Control Panel -> Status page, section Versions and Serials Numbers, for the validity of the Firmware support. A firmware image will fail to install if the SLA is not active. Contact Avateq Support for more details.

AVQ1020(1st Gen) - FW639 (June 10, 2019)

List of Changes

ChangeTypeApplicable ModelsApplicable Standards*
Performance issuesFIXAVQ1020 (1stG)NSS

* NSS - Not Standard Specific

Links to Firmware Images

ModelLink
AVQ1020 (1stGen)rootfs.web
uImage.web

Upgrade Instructions: Firmware and License Upgrade

IMPORTANT!
Please check your SLA license expiry date on the Control Panel -> Status page, section Versions and Serials Numbers, for the validity of the Firmware support. A firmware image will fail to install if the SLA is not active. Contact Avateq Support for more details.